          5. FUEL SYSTEM                                                        AGILITY 50
                                                                      Fuel Unit Wire
FUEL UNIT
 REMOVAL
 Remove the related parts.
 Disconnect the fuel unit wire connector.
 Turn the fixed plate on the fuel unit,take the
 fuel unit off.
     Do not bend the float arm on the fuel
     unit,otherwise the figure on the fuel
     meter will not correct.



                                                  Fuel Tank
 INSTALLATION
 Inspet if the fuel unit is damaged,or harden.
 Assemble the fuel unit in the reverse order
 of disassembly.
 · Align the groove on the fuel unit with
     the angle on the fuel tank.
   · Inspect if the fuel tank leaked after
     installing and filling the gasoling.



                                                  Fuel Unit            Align Mark


                                                                            air cleaner
 AIR CLEANER
 Loosen the air cleaner connecting tube band
 screw.
 Disconnect the clinhead cover breather tube
 from the air cleaner.
 Remove the two bolts and air cleaner case.




                                                              bolts