          16. CHARGING SYSTEM                                                                Pulsar       CK   125

                                                                                        Regulator/Rectifier
 REGULATOR/RECTIFIER
 REMOVAL
 Remove the regulator/rectifier lock nut and
 disconnect the regulator/rectifier wire
 coupler.
 Measure the resistances between the
 regulator/rectifier wire terminals. Replace
 the regulator/rectifier if the readings are not
 within the specifications in the table below.

                                                                                      Coupler


                                                                        Pink                  Black Green
 · Due to the semiconductor in circuit, it
      is necessary to use a specified tester for
      accurate testing. Use of an improper
      tester or measurements in an improper
      range may give false readings.
    · Use a Sanwa Electric Tester or Kowa
      Electric Tester for testing.



                                                                                      Red           Yellow




 Testing Range                                     (+)Probe
 Range for the Sanwa Tester: xK                               Pink   Yellow     Red         Green     Black
                                              (-)Probe
 Range for the Kowa Tester: x100
                                                   Pink                        4-7K                    


                                               Yellow                          4-7K                    


                                                   Red                                                 


                                                   Green      4-6K   4-6K      13-17K                 1-2K


                                                   Black      4-7K   4-7K      13-17K       1-2K

                                              Note: The readings in this table are taken with a Sanwa
                                                    Tester.




                                                                                                      16-6