          17. CHARGING SYSTEM                                                      STRYKER 125/150


 BATTERY
 REMOVAL
 Remove the left side cover.
 First disconnect the battery negative cable
 and then the positive cable.
 Remove the two battery set plate lock nuts.




 BATTERY CHARGING
 Connect the charger positive cable to the
 battery positive cable.
 Connect the charger negative cable to the
 battery negative cable.

 CHARGING METHOD:
 Standard Charging: 0.7A charging 10 hours


 Quick Charging: 3A charging 23 hours




      Warning
                                                                  Specific Gravity VS Charging Time
  · Keep flames and sparks away from a
    charging battery to prevent igniting the
    hydrogen gas produced by the battery.
  · Turn power ON/OFF at the charger, not
                                               Specific Gravity




    at the battery terminals to prevent
    sparks near the battery.
  · Discontinue charging if the electrolyte
    temperature exceeds 45.

 Do not quick charge the battery. Quick                             Charging Time
   charging should only be done in an
   emergency.