13. FUEL INJECTION SYSTEM Downtown 300i ABS
SELF-DIAGNOSTIC
PROCEDURES WITHOUT
DIAGNOSTIC TOOL
SELF-DIAGNOSTIC PROCEDURES
It can be performed without diagnostics
program.
Place the scooter on its main stand.
RUN
Put the side stand up and the engine stop
switch is at "RUN".
Turn key to On position.
The CELP will be lighting for two seconds
and then off.
If the engine has problem, the CELP will Upward side
blink to show the failure codes. stand
There're 11 failure codes for the KEHIN
system.
If the vehicle gets more failure codes, the
CELP will be blinking from a lower number,
then show the higher number after three
seconds. All failure codes would be
appeared repeatedly.
Battery warning indicator
No matter when the "CELP" illuminated
while riding condition, should find out
the cause of the problem as soon as Fi indicator
13-7