17. IGNITION SYSTEM GRAND DINK 125/150
E PC IGN
(Green) (Blue/Yellow) (Black/Yellow)
CDI UNIT
RESISTANCE INSPECTION
Measure the resistance between the terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
· Due to the semiconductor in circuit, it
is necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
· Use a Sanwa Electric Tester (07308- E EXT SW
(Green/White) (Black/Red) (Black/White)
0020000) or Kowa Electric Tester
(TH-5H).
· In this table, "Needle swings then
returns" indicates that there is a
charging current applied to a condenser.
The needle will then remain at ""
unless the condenser is discharged.
Use the x K range for the Sanwa Tester.
Use the x 100 range for the Kowa Tester.
Unit: K
(+)Probe E
SW EXT PC IGN
(Green ·
(Black/White) (Black/Red) (Blue/Yellow) Green/White) (Black/Yellow)
(-)Probe
SW
(Black/White)
EXT 1-10 100-200 250-450
(Black/Red)
PC 50-90 30-100 20-80
(Blue/Yellow)
E
(Green · 5-20 1-10 5-40
Green/White)
IGN
(Black/Yellow)
17-5