10. A.C. GENERATOR/STARTER CLUTCH K-XCT 125i
SERVICE INFORMATION
GENERAL INSTRUCTIONS
All servicing operations and inspections in this section can be made with the engine installed.
Drain the coolant before removing the right crankcase cover.
Be careful not to drain the coolant when the engine temperature is high. (Perform this operation
when the engine is cold.)
Drain the coolant into a clean container.
Drain the engine oil into a clean container before removing the right crankcase cover.
When the right crankcase cover is installed, fill with the recommended engine oil and coolant.
Then, bleed air from the water jacket.
SPECIFICATIONS
Engine oil: SAE 15W/40#
API-SJ
Oil capacity at change: 1.0 L
Coolant: distilled water + coolant concentrate
Coolant capacity: 0.87L
SPECIAL TOOLS
Flywheel puller A120E00003
Flywheel holder A120E00021
TORQUE VALUES
Flywheel nut : 5.0~6.0 kgf-m
TROUBLESHOOTING
Starter motor rotates but engine fail to start
Faulty starter clutch
Starter motor rotates reversely
Weak battery
10-2