          12. FUEL SYSTEM                                                   LIKE 200i


                                                  Fuel Cut-off Relay
ROLL SENSOR (FUEL CUT-OFF RELAY)

The engine should be stopped running when the
vehicle inclines over 65° for safety. When you
place the vehicle back to normal situation, you
have to key-off and key-on the switch, then it
can be restarted.

Standard:
Normal:   0.4~1.4V
Over 65°:   3.7~4.4 V




  Forbidding adjust TP screw. The best
  engine working condition had already been
  adjusted by KYMCO, if any change, maybe
  cause to engine problem.




                                                  TP screw



                                                                  12-24