15. ELECTRICAL EQUIPMENT LIKE 50 2T
Resister
RESISTOR INSPECTION
Remove the frame front cover. ( 12)
Measure the resistance between the
resistor with ground.
Resistances:
Resistor: 4.55.5
Faulty resistor is the cause of faulty
operation of the auto bystarter.
REGULATOR/RECTIFIER INSPECTION
Remove the front cover. ( 12)
Disconnect the regulator/rectifier wire
coupler and remove the bolt to remove the
regulator/rectifier.
Measure the resistances between the
terminals.
Replace the regulator/rectifier if the
readings are not within the specifications in
the table below.
· Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing. Use of an
Regulator/Rectifier
improper tester in an improper range
may give false readings.
· Use a Sanwa Electric Tester (07208-
0020000) or Kowa Electric Tester
(TH-5H). The proper range for
testing is listed below.
Black Green
Pink
Model Brand Range
SP-10D Sanwa K
TH-5H Kowa 100
Red Yellow