16. INSTRUMENT/SWITCHES/LIGHTS LIKE 50 2T
Fuel Unit
INSTALLATION
The installation sequence is the reverse of
removal.
· Install the fuel unit at the connect
position.
OIL METER
INSPECTION
Remove the met-in box. ( 12-4)
Remove the frame body cover. ( 12-4)
Disconnect the oil meter wire connectors
and remove the oil meter. Keep the oil
Wire Connector
meter float at the lower position.
Measure the resistances between the wire
terminals as and shown in the left Oil Meter B
G/R G
figure. B
Wire Terminals Resistance
Green/Red(+)Black(-) 46
Green(-)Black(+)
Before removing the oil meter, be sure
to drain the motor oil and do not allow
sparks or flames near the working area. Float
Oil Meter Operation Inspection
Connect the oil meter wire connectors and
turn the ignition switch ON.
Measure the resistance between the wire
terminals with the float at upper position.
Green/Red(+)Black(-) About 300
Light OFF
Before performing the following test, Light OFF
operate the turn signals to determine
that the battery circuit is normal. Light ON 4.51.0mm
Move the oil meter float up and down to see Oil Indicator
Light
if the oil indicator light will go out and come
on.
If the oil indicator light does not light,
check for burned bulb, loose wire or
connector. After correction, check again
according to the method mentioned
above.
3