17. BATTERY/CHARGING SYSTEM MXU 500 IRS
ALTERNATOR STATOR
REMOVAL/INSPECTION/
INSTALLATION
REMOVAL
Drain the engine oil (refer to the "ENGINE
OIL" section in the chapter 3).
Disconnect the alternator stator connectors.
Alternator Stator Connectors
Oil Filler Plug
Remove the starter pulley (refer to the
"STARTER PULLEY
REMOVAL/INSPECTION/INSTALLATI
ON" section in the chapter 19).
Remove the oil filler plug.
Remove the fourteen bolts and then remove
the right crankcase cover.
Right Crankcase Cover
17-11