15. ELECTRICAL EQUIPMENT SUPER 9 50
CDI UNIT INSPECTION Coupler
Open the front tool box and remove the bolt.
Remove the front tool box. ( 2-4)
Disconnect the CDI coupler and remove the
CDI unit.
CDI Unit
CDI CIRCUIT INSPECTION
Measure the resistance between the terminals.
Replace the CDI unit if the readings are not Black/ Yellow Green
within the specifications in the table below.
· Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
· Use a Sanwa Electric Tester or Kowa
Electric Tester (TH-5H).
· In this table, "Needle swings then
returns" indicates that there is a charging
current applied to a condenser. The needle
will then remain at "" unless the
condenser is discharged.
Blue/ Yellow Black/ Blue
Use the x K range for the Sanwa Tester.
Use the x 100 range for the Kowa Tester.
Unit: K
Probe
Black/ Blue/ Green Black/
(-)Probe Blue Yellow Yellow
Black/
1~100
Blue
Blue/
100~ 1~100
Yellow
Green 1~
Black/
1~100 0.1~50
Yellow
15-10