19. STARTER SYSTEM UXV 500
Starter Motor Cable
STARTER MOTOR
INSPECTION
Disconnect the starter motor cable from the
starter MAG.
Turn the ignition switch to "ON".
Connect the starter motor cable directly to the
battery positive terminal.
If the starter motor does not turn, the starter
motor is faulty.
Rubber Cap
REMOVAL
Remove the carburetor
Turn the ignition switch turned to "OFF"
Remove the two mounting bolts and starter
motor.
Release the rubber cap and remove the
terminal nut to disconnect the starter motor
cable from the starter motor.
Bolts Nut
INSTALLATION
O-ring
Coat a new O-ring with engine oil and install
it into the starter motor groove.
Connect the starter motor cable to motor
terminal with the terminal nut and tighten it.
Install the starter motor into the crankcase.
Install the two mounting bolts and tighten them
securely.
19-4