16. CHARGING SYSTEM Pulsar CK 125
SERVICE INFORMATION......................16-1 BATTERY CHARGING ..........................16-4
TROUBLESHOOTING.............................16-2 A.C. GENERATOR .................................16-5
BATTERY .................................................16-3 REGULATOR/RECTIFIER.....................16-6
SERVICE INFORMATION
GENERAL INSTRUCTIONS
· Battery fluid level should be checked regularly. Fill with distilled water when necessary.
· Do not quick charge the battery. Quick charging should only be done in an emergency.
· Remove the battery from the motorcycle for charging. If the battery must be charged on the
motorcycle, keep sparks and flames away from a charging battery. The hydrogen gas produced
by a charging battery is very flammable and can explode.
· When inspecting the A.C. generator, use an electric tester.
· Route the charging system wires properly to avoid shorted wire due to wires being twisted or
kinked.
SPECIFICATIONS
Battery capacity 12V6AH
Electrolyte specific gravity 1.2601.280 20
Charging current 0.7A max.
Charging rpm 2,100 rpm (min.)
A.C. generator 1.1A min./3,000 rpm
Capacity
Regulator/Rectifier No contact point type
Charging coil resistance 0.20.3
TORQUE VALUES
A.C. generator stator bolt 0.81.2kg-m
A.C. generator flywheel bolt 4.05.2kg-m
SPECIAL TOOLS
Flywheel holder E021
Flywheel puller E005
TESTING INSTRUMENTS
Kowa electric tester
Sanwa electric tester
16-1