20. EVAPORATIVE EMISSION CONTROL SYSTEM Downtown 300i ABS
SERVICE INFORMATION
GENERAL INSTRUCTIONS
· Do not smoke or allow flames or sparks near the working area.
· Note the locations of tubes for proper installation.
· Replace any damaged tube with a new one.
· Make sure to tighten the connector of each tube securely.
TOOLS
· Vacuum pumpA937014
· Pressure pump
SPECIFICATIONS
Purge control valve vacuum pressure 45mm/Hg
Charcoal canister capacity 90cc
A. LEAKAGE TEST PIPING DIAGRAM
Charcoal Canister/ Purge Control Valve
Manifold
Fuel Injector Absolute
Throttle Body Pressure Sensor
Fuel Tank
Air Cleaner
Air By Pass Valve
20-3