          16. BATTERY/CHARGING SYSTEM                           GRAND DINK 125/150



 SPECIAL TOOLS
 Universal holder
 Flywheel puller


 TROUBLESHOOTING
 No power                       Intermittent power
 · Dead battery                 · Loose battery cable connection
 · Disconnected battery cable   · Loose charging system connection
 · Fuse burned out              · Loose connection or short circuit in
 · Faulty ignition switch         ignition system


 Low power                      Charging system failure
 · Weak battery                 · Loose, broken or shorted wire or connector
 · Loose battery connection     · Faulty regulator/rectifier
 · Charging system failure      · Faulty A.C. generator
 · Faulty regulator/rectifier




16-3