1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 315 320 325 330 335 340 345 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 433
          19. STARTING SYSTEM                                       K-XCT 125i



 START RELAY INSPECTION

 Release the rubber cap (1) and remove the nut
 (2), then disconnect the start motor cable.
 Turn the ignition switch to "ON"position.

 Squeeze and hold the brake lever fully then
 push the starter switch.
 The coil is normal if the start relay switch
 clicks.




 Release the rubber caps and remove the nuts,
 then disconnect the start motor cable, battery   (2)   (1)
 positive cable and harness wire.
 Disconnect the start relay connector and then
 remove start relay.




                                                          (3)




 Connect a fully charged 12 V battery positive
 wire to the relay switch Yellow/Red wire
 terminal and negative wire to the
 Green/Yellow wire terminal.

 There should be continuity between the cable
 terminals while the battery is connected, and
 no continuity when the battery is
 disconnected.




19-5