15. IGNITION SYSTEM Mongoose/KXR 90/50
CDI Unit
CDI UNIT INSPECTION
Remove seat. ( 2-3)
Disconnect the CDI coupler and remove the
CDI unit.
Measure the resistance between the
terminals using the electric tester.
· Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
· Use a YF-3501 Electric Tester.
· In this table, "Needle swings then
returns" indicates that there is a charging
current applied to a condenser. The needle
will then remain at "" unless the
condenser is discharged.
Mongoose/KXR 90(OFF ROAD) Unit: M
Probe
Black/Yellow Black
Black Black/ Blue/
Green
(-)Probe Yellow Yellow
Black
Black/
Yellow
Blue/
Yellow
Green 4.9~5.5 4.9~5.5 4.9~5.5
Blue/Yellow Green
Note: The readings in this table are taken
with a YF-3501 Tester.
15-5