17. IGNITION SYSTEM GRAND DINK 250
CDI UNIT
RESISTANCE INSPECTION
Measure the resistance between the terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
· Due to the semiconductor in circuit, it
is necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
· In this table, "Needle swings then
returns" indicates that there is a
charging current applied to a condenser.
The needle will then remain at "" L/Y G/GR
unless the condenser is discharged.
Unit:
(+)
(-) L/Y B/Y G/GR G/W B/W G/B V/R V/B V/G G
L/Y 67~125K 36~67K 110~200K 36~67K 36~67K
B/Y 11~22M 11~22M 0.5~2 K 11~22M 11~22M 11~22M 11~22M
G/GR
G/W 67~125K 36~67K 110~200K 36~67K 36~67K
B/W 11~22M 0.5~2 K 11~22M 11~22M 11~22M 11~22M 11~22M
G/B
V/R 36~67K 36~67K 72~133 K 2~5 K 2~5 K
V/B 110~200K 110~200K 72~133 K 72~133 K 72~133 K
V/G 36~67K 36~67K 2~5 K 72~133 K 0.1~1
G 36~67K 36~67K 2~5 K 72~133 K 0.1~1
17-5