          17. EXHAUST EMISSION CONTROL
                                                                           LIKE 50 2T
     SYSTEM
ECONDARY AIR CLEANER / AIR                        Secondary Air Cleaner / A.I.C.V.
INJECTION CONTROL VALVE (A.I.C.V.)
  REMOVAL
  Remove the seat. ( 2-4)
  Remove the body cover.
  Disconnect the secondary air cleaner
  /(A.I.C.V) connecting tube.




  INSPECTION
  Remove two screws on the air cleaner/air                            Air Inlet Tube
                                                                              B lt
  injection control valve.                               Air Outlet Tube
  Replace new one when the filter elements
  obstruct considerable dirt.


  INSTALLATION
  The installation sequence is the reverse of
  removal.




  · The secondary air cleaner must be
        assembled and installed properly to     Air Inlet Tube
        avoid dust entering the air cleaner.
      · When installing, be careful not to
        bend or twist the tubes and check for
        proper installation.
      · The tube length is very important to
        its performance, use the tube of
        same specification for replacement.




                                                                                       17-3