7. ENGINE REMOVAL/INSTALLATION MXU 500 IRS
Breather Hose
Disconnect the breather hose from cylinder
head cover and remove the mounting nut
from breather housing holder, then remove
the breather housing.
Vacuum Hose Starter Cable
Disconnect the vacuum hose from intake
pipe.
Slide the rubber sleeve back to expose the
starter motor wire nut.
Remove the starter motor cable nut for
disconnect the starter motor cable.
Remove the bolt and then disconnect the
engine ground cable from starter motor.
Rubber Sleeve Engine Ground Cable
Ignition Pulse Generator
Remove the A.C.Generator and ignition
pulse generator connectors.
A.C. Generator Connector