1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 224
          13. FUEL INJECTION SYSTEM                                          People GT 300i


 SELF-DIAGNOSTIC                                                          RUN
 PROCEDURES WITHOUT
 DIAGNOSTIC TOOL

 SELF-DIAGNOSTIC PROCEDURES

 It can be performed without diagnostics
   program.

 Place the scooter on its main stand.
 Put the side stand up and the engine stop
 switch is at "RUN".
  Turn key to On position.
  The CELP will be lighting for two seconds
  and then off.
  If the engine has problem, the CELP will
  blink to show the failure codes.             Upward side
  There're 11 failure codes for the KEHIN      stand
  system.
 If the vehicle gets more failure codes, the
 CELP will be blinking from a lower number,
 then show the higher number after three
 seconds. All failure codes would be                 Battery warning indicator
 appeared repeatedly.


 No matter when the "CELP" illuminated
   while riding condition, should find out
   the cause of the problem as soon as




                                                                         Fi indicator