people gt 300 i Workshop-manual : Page 141

Microfiches
Image preview

Page 139

Image preview

Page 140

Image preview

Page 142

Image preview

Page 143

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 224
          13. FUEL INJECTION SYSTEM                                              People GT 300i




 FUEL PUMP

 INSPECTIION
                                                  Full Position
 Put the side stand up and the engine stop
 switch is at "RUN"

 Disconnect the fuel pump/fuel unit
 connector.
 Connect the multimeter (+) probe to the
 Red/Black terminal and the multi-meter (-)
 probe to the Green terminal.
 Turn the ignition switch to "ON" and
 measure the voltage between the terminals.
                                                                          Green
 It should be shown the current battery
 voltage for a few seconds.

 If there is still battery voltage, replace the
 fuel pump.                                                                    Yellow/White
 If there is not any battery voltage, inspect
 the following:
  Fuse B (10 A)
  Fuel cut-off relay
  ECU

 Measure the resistance between the
 Red/Black and Green terminals of the fuel                        Empty Position
 pump side connector.
 Standard (at 20°C/68°F): 1.90.3 


 Fuel level sensor inspection

 Measure the resistance between the
 Yellow/White and Green terminals of the
 fuel pump side connector.

 Standard (at 20°C/68°F):
 Float at full position         110033 
 Float at empty position         1003 




13-13