16. STARTING SYSTEM AGILITY 50
Starter Relay
STARTER RELAY TEST
Remove the battery cover.
Disconnect the 4P connector from the starter
relay and remove the starter relay.
Connect the starter relay (D) terminal to the
12V battery positive (+) terminal and the
relay (C) terminal to the battery negative (-)
terminal. Check for continuity between the
starter relay (A) and (B) terminals. The
relay is normal if there is continuity.
Bolts
STARTER MOTOR INSTALLATION
Apply engine oil to the starter motor O-ring
and install the starter motor.
Tighten the two mounting bolts.
Connect the starter motor cable connector.
Connector Starter Motor