          16. ELECTRICAL EQUIPMENT                                            LIKE 200i



 BATTERY REMOVAL
 Remove the battery cover.
 Disconnect the battery cables .

   First disconnect the battery negative (-)
   cable and then the positive (+) cable.

 Remove the battery.
 The installation sequence is the reverse of
 removal.

 BATTERY CHARGING (OPEN CIRCUIT
 VOLTAGE) INSPECTION
 Remove the battery cover and disconnect
 the battery cables.
 Measure the voltage between the battery            Battery Cover
 terminals.
 Fully charged : 13.0V13.2V
 Undercharged : 12.3V max.

   Battery charging inspection must be
   performed with an electric tester.

 CHARGING METHOD
 Connect the charger positive (+) cable to
 the battery positive (+) cable.
 Connect the charger negative (-) cable to
 the battery negative (-) cable.
 · Keep flames and sparks away from a
     charging battery.
   · Turn power ON/OFF at the charger, not
     at the battery terminals to prevent sparks
     near the battery.
   · Charge the battery according to the
     current specified on the battery surface.

 Charging current:Standard: 0.4A
                    Quick       : 4A
 Charging time : Standard: 5 hours
                    Quick       : 0.5 HOUR
 After charging: Open circuit voltage: 12.8V min.
 · Quick charging should only be done in
     an emergency.
   · During quick charging, the battery
     temperature should not exceed 45.
   · Measure the voltage 30 minutes after
     the battery is charged.