          14. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                           SUPER8 125

 BATTERY                                             Battery Cover
 REMOVAL
 Remove the battery cover screws on the floor
 board.
 Open the battery cover and remove the
 battery by removing the bolt and band.
 First disconnect the battery negative (-) cable
 and then the positive (+) cable.
   When disconnecting the battery positive
   (+) cable, do not touch the frame with
   tool; otherwise it will cause short circuit
   and sparks to fire the fuel.
 The installation sequence is the reverse of
 removal.                                                                             battery
   First connect the positive (+) cable and the
   negative (-) cable to avoid short circuit.
 BATTERY VOLTAGE (OPEN CIRCUIT
 VOLTAGE) INSPECTION
 Remove the floor board.
 Open the battery cover and disconnect the
 battery cables.
 Measure the voltage between the battery
 terminals.
 Fully charged : 13.1V
 Undercharged : 12.3V max.
 Battery charging inspection must be                positive (+) cable     negative (-) cable
   performed with a voltmeter.
 CHARGING
 Connect the charger positive (+) cable to the
 battery positive (+) terminal.
 Connect the charger negative (-) cable to the
 battery negative (-) terminal.
 · Keep flames and sparks away from a
   charging battery.
· Turn power ON/OFF at the charger, not
  at the battery terminals to prevent
  sparks near the battery to avoid
  explosion.
· Charge the battery according to the
         t      ifi d   th b tt
 · Quick charging should only be done in
   an emergency.
 · Measure the voltage 30 minutes after                              Red     Power Lamp (Red)
   the battery is charged.                              Black                    Charging Lamp (Green)
 Charging current: Standard : 0.4A
                    Quick : 4A
 Charging time : Standard : 510 hours
                    Quick : 30 minutes
 After charging: Open circuit voltage: 12.8V min.
 Note: The battery temperature should not
        exceed 45during charging.

14-3