3. INSPECTION/ADJUSTMENT                                MXU 500 IRS


 6. Remove the oil level check bolt (3).
     Make sure the oil level reaches the oil
     level check hole.
 7. Install and tighten the oil filler bolt and
     oil level check bolt to the specified
     torque.

 Torque:
 Oil filler cap:
                           3.5 kgf-m (35 N-m,)
 Oil level check bolt:
                                                  (3)
                             1 kgf-m (10 N-m,)
 Be sure no foreign material enters the
   crankcase.




 SPARK ARRESTER

 Be sure the exhaust pipe and muffler are
 cool before cleaning the spark arrester.

 1. Remove the three bolts (1).




 2. Remove the spark arrester (2) and the
    gasket (3) from the muffler.




3-19