13. FUEL INJECTION SYSTEM People GT 125i
O2 SENSOR
Measure the resistance of the O2 sensor heater.
(2 white wire pin)
Standard (20°C/68°F ): 6.7 ~9.5
Connect the PDA or KYMCO Fi diagnostic tool.
Enter the Data Analyze
Check Page 05
Turn the ignition switch to the "ON" position.
Starting engine till the O2 heater activation is 0~1
ON.
If data is incorrect, the O2 sensor is problem.
ON
13-15