15. ELECTRICAL EQUIPMENT SUPER 9 50
STARTER RELAY INSPECTION Starter Relay
Open the front tool box and remove the bolt.
Remove the front tool box. ( 2-4)
Disconnect the starter relay coupler and then
remove the starter relay.
Connect the starter relay green/yellow Red Yellow/Red
terminal to the 12V battery positive (+)
terminal and the relay yellow/red terminal to
the battery negative (-) terminal. Check for
continuity between the starter relay red and
red/white terminals. The relay is normal if
there is continuity.
Red/White Green/Yellow
STARTER MOTOR REMOVAL Bolts
Disconnect the starter motor cable.
Remove the two bolts attaching the starter
motor and remove the starter motor.
The installation sequence is the reverse of
removal.
Starter Motor
15-12