17. BATTERY/CHARGING SYSTEM DOWNTOWN125i VOLTAGE INSPECTION Remove the battery cover . Measure the battery voltage using a commercially available digital multimeter. Voltage (20C/68C): Fully charged: 1313.2 V Insufficient charged: below 12.3 V BATTERY CHARGING Remove the battery Connect the charger positive (+) cable to the battery positive (+) terminal. Connect the charger negative (-) cable to the battery negative (-) terminal. Turn the power ON/OFF at the battery charger, not at the battery terminals. Charging current time: Standard: 1 .2A/510h Quick: 5A/1h Quick charging should only be done in an emergency; slow charging is preferred. For battery charging, do not exceed the charging current and time specified on the battery. Using excessive current or extending the charging time may damage the battery. 17-5