5. FUEL SYSTEM MXU 250R/300R
SERVICE INFORMATION
GENERAL INSTRUCTIONS
Gasoline is very dangerous. When working with gasoline, keep sparks and flames away
from the working area.
Gasoline is extremely flammable and is explosive under certain conditions. Be sure to
work in a well-ventilated area.
· Do not bend or twist control cables. Damaged control cables will not operate smoothly.
· When disassembling fuel system parts, note the locations of O-rings. Replace them with new
ones during reassembly.
· Before float chamber disassembly, loosen the drain screw to drain the residual gasoline into a
clean container.
· After the carburetor is removed, plug the intake manifold side with a clean shop towel to prevent
foreign matters from entering.
· When cleaning the carburetor air and fuel jets, the O-rings and diaphragm must be removed first
to avoid damage. Then, clean with compressed air.
· When the motorcycle is not used for over one month, drain the residual gasoline from the float
chamber to avoid erratic idling and clogged slow jet due to deteriorated fuel.
SPECIFICATIONS
Item MXU 250R MXU 300R
Type PD CVK
Venturi dia. 22 31
Main jet No. 98 112
Adjust method Piston Valve Piston
Idle speed 1500100rpm 1600100rpm
Throttle grip free play 14mm 14mm
Air screw opening 1 1/81/2 1 1/81/2
5-2