17. BATTERY/CHARGING SYSTEM MXU 550EXI/MXU500I
CHARGING VOLTAGE INSPECTION
Be sure that the battery is in good condition
before performing this test.
Do not disconnect the battery or any
cable in the charging system without
first switching off the ignition switch.
Failure to follow this precaution can
damage the tester or electrical
components.
Start the engine and warm it up to the
operating temperature; stop the engine.
Connect the multi-meter between the positive
and negative terminals of the battery.
To prevent short, make absolutely certain
which are the positive and negative terminals
or cable.
With the headlight on and turned to the high
beam position, restart the engine.
Measure the voltage on the multi-meter when
the engine runs at 5000 min (rpm).
Standard:
14.01.0V / 5000 rpm
ALTERNATOR CHARGING COIL
INSPECTION
Disconnect the alternator connector.
Alternator Connector
17-6