          11. CRANKCASE/CRANKSHAFT                                            GRAND DINK 250


 Measure the crankshaft runout.
 Service Limit: 0.10mm replace if over




 Measure the crankshaft bearing play.                  Play
 Service Limits:
                                                                                  Play
   Axial : 0.20mm replace if over
   Radial: 0.05mm replace if over




                                                   Axial
                                                                               Radial




 CRANKCASE ASSEMBLY
 Clean off all gasket material from the
 crankcase mating surfaces.
 · Avoid damaging the crankcase mating
     surfaces.




                                                                    Oil Seal
 Install a new oil seal into the left crankcase.




                                                           Left Crankcase

11-5