12. COOLING SYSTEM GRAND DINK 250
Radiator
RADIATOR INSTALLATION
Install the radiator on the radiator bracket
with the two bolts and one nut.
Bolts Nut
.
Upper Hose
Connect the upper and lower hoses and
secure them with hose bands.
Connect the thermostatic switch wire and
fan motor wire couplers.
Thermostatic Switch Wire Lower Hose
Overflow Tube
Connect the overflow tube and secure with
the tube clamp.
Fill the radiator with coolant. ( 3-9)
Connect the vent tube to the radiator filler.
After installation, check for coolant leaks.
If you want to refill the coolant , the
following procedure must be checked.
1. Please make the radiator filler and the
air vent tube to be separated.
2. Then start the engine , filled in the
coolant till the coolant flowed out
from the air vent tube.
3. Put the air vent tube on. Air Vent Tube
12-8