14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR ATV 150/125
A.C. GENERATOR CHARGING
COIL
The inspection of A.C. generator
charging coil can be made with the
engine installed.
INSPECTION
Disconnect the A.C. generator pink and
yellow wires and measure the resistance
between the pink and yellow wires.
Resistance: 0.2 (at 20)
Replace the A.C. generator charging coil if
the reading is not within the specifications.
14-7