5. FUEL SYSTEM MXU 300/250 AIR CLEANER HOUSING Breather Hose REMOVAL/INSTALLATION Remove the seat (see page 2-3). Remove the side covers (see page 2-6). Remove the clip and disconnect the crankcase breather hose from the crankcase. Loosen the carburetor-to-air cleaner connecting tube band screw. Band Screw Trim Clip Remove the intake air duct trim clip. Remove the mounting bolts and then remove the air cleaner housing from the carburetor and the intake duct. Installation is in the reverse order of removal. Bolts 5-15