3. INSPECTION/ADJUSTMENT MXU 250R/300R
Remove the drain plug (2) to drain the oil.
Reinstall the drain plug and tighten to
specified torque.
Torque: 2 kgf-m (20 Nm, 15 lbf-ft)
Fill the engine with recommended oil (SAE
#90).
Oil Capacity (MXU 250R):
At disassembly : 400 cc (0.35 lmp qt,
0.42 Us qt)
At change : 300 cc (0.26 lmp qt,
0.32 Us qt)
Oil Capacity (MXU 300R):
At disassembly : 600 cc (0.52 lmp qt,
0.64 Us qt)
At change : 500 cc (0.43 lmp qt,
0.53 Us qt)
Install the oil filler bolt and tighten to
specified torque.
Torque: 2 kgf-m (20 Nm, 15 lbf-ft)
Start the engine and warm up for a few
minutes. While warming up, check for oil
leakage. If oil leakage is found, stop the
engine immediately and check for the cause.
Make sure that the sealing washer is in
good condition.
3-13