          19. IGNITION SYSTEM                                MYROAD 700i


IGNITION PULSE GENERATOR
INSPECTION
Remove the luggage box.
Disconnect the ignition pulse generator
connector.
Measure the ignition pulse generator resistance
between the Black wire and Blue wire.
Standard: 10.510%K (20C/68F)




IGNITION COIL
REMOVAL/INSTALLATION
Remove the floorboard.
Disconnect the spark plug cap from the spark
plug.

Disconnect the ignition coil primary connectors.
Remove the two nuts and the ignition coil.

Installation is in the reverse order of removal.



Ignition coil inspection.
Standard: 3.57~4.83                                  Ignition Coil
          10.42~14.79K




19-3