1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 186
          14. BATTERY/CHARGING SYSTEM/
    A.C. GENERATOR                                                          PEOPLE 125/150


                                                   After charging: Open circuit voltage: 12.8V min.
 BATTERY
 REMOVAL
 Remove the frame cover screws.
 Open the cover and remove the battery cover
 screw.
 First disconnect the battery negative (-) cable
 and then the positive (+) cable.
   When disconnecting the battery positive
   (+) cable, do not touch the frame with
   tool; otherwise it will cause short circuit
   and sparks to fire the fuel.
 The installation sequence is the reverse of
 removal.
   First connect the positive (+) cable and then
   negative (-) cable to avoid short circuit.
 BATTERY VOLTAGE (OPEN CIRCUIT
 VOLTAGE) INSPECTION
 Open the battery cover and disconnect the
 battery cables.
 Measure the voltage between the battery
 terminals.
 Fully charged : 13.1V
 Undercharged : 12.3V max.
   Battery charging inspection must be
   performed with a voltmeter.
                                                        Battery Cover Screw
 CHARGING
 Connect the charger positive (+) cable to the
 battery positive (+) terminal.
 Connect the charger negative (-) cable to the
 battery negative (-) terminal.
   · Keep flames and sparks away from a
     charging battery.
   · Turn power ON/OFF at the charger, not
     at the battery terminals to prevent
     sparks near the battery to avoid
     explosion.
   · Charge the battery according to the
                  ifi d    h b
   · Quick charging should only be done in
      an emergency.
   · Measure the voltage 30 minutes after
      the battery is charged.

 Charging current : Standard : 0.7A
                    Quick : 3.0A
 Charging time : Standard : 5 10 hours
                    Quick : 30 minutes
                                                                                           14-4