people 250 s Workshop-manual : Page 211

Microfiches
Image preview

Page 209

Image preview

Page 210

Image preview

Page 212

Image preview

Page 213

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 243
          16. BATTERY/CHARGING SYSTEM                                                   PEOPLE/PEOPLE S 250



 SERVICE INFORMATION
 GENERAL INSTRUCTIONS
 
    The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and
    eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and
    get prompt medical attention

 · The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
   long time, its service life will be shortened. Generally, the capacity of a battery will decrease
   after it is used for 23 years. A capacity-decreased battery will resume its voltage after it is
   recharged but its voltage decreases suddenly and then increases when a load is added.
 · When a battery is overcharged, some symptoms can be found. If there is a short circuit inside
   the battery, no voltage is produced on the battery terminals. If the rectifier won`t operate, the
   voltage will become too high and shorten the battery service life.
 · If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
   months.
 · A new battery filled with electrolyte will generate voltage within a certain time and it should be
   recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
 · Inspect the charging system according to the sequence specified in the Troubleshooting.
 · Do not disconnect and soon reconnect the power of any electrical equipment because the
   electronic parts in the regulator/rectifier will be damaged. Turn off the ignition switch before
   operation.
 · It is not necessary to check the MF battery electrolyte or fill with distilled water.
 · Check the load of the whole charging system.
 · Do not quick charge the battery. Quick charging should only be done in an emergency.
 · Remove the battery from the motorcycle for charging.
 · When replacing the battery, do not use a traditional battery.
 · When charging, check the voltage with an electric tester.

 SPECIFICATIONS
                             Item                                           Standard
                                   Capacity                                 12V10AH
                          Voltage           Fully charged                     13.2V
       Battery             (20)            Undercharged                       12.3V
                               Charging current                      STD: 1.2 A Quick: 5.0A
                                Charging time                       STD: 5-10hr Quick:60min
                                   Capacity                              180W/5000rpm
   A.C. Generator        Charging coil resistance (20)          YellowYellow         1.62.5
                                 Charging rpm                          1300rpm max (14V)
                            Charging performance                       10.5A min/5000rpm
 Regulator/Rectifier                Limit voltage                            14.50.5V

 TESTING INSTRUMENTS                                TORQUE VALUES
 Ammeter                                            Pulser coil bolt         4.9N-m
 Electric tester: YF-3501                           Coil lock bolt           8.8N-m
 Tachometer                                         Flywheel nut             58.8N-m

                                                                                              16-2