14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR AGILITY CITY 125
SPECIFICATIONS
Item Standard
Capacity/Model 12V-4AH
Voltage Fully charged 13.1V
Battery (20) Undercharged 12.3V
Charging current STD: 0.4A Quick: 4.0A
Charging time STD: 510hr Quick: 30min
Capacity 0.144KW/5000rpm
A.C. Generator
Charging coil resistance (20) YellowPeach 0.11.0
Type Single-phase full-wave SCR
Regulator/Rectifier
Limit voltage
Charging 14.50.5V/5000rpm
Resistance (20) 5W12
Resistor
TORQUE VALUES
Pulser coil bolt 0.45~0.6kgf-m
Stator bolt 0.8~1.2kgf-m
Flywheel nut 3.5~4.5kgf-m
Cooling fan bolt 0.8~1.2kgf-m
SPECIAL TOOLS
Universal holder
Flywheel puller
TESTING INSTRUMENTS
Kowa electric tester
Sanwa electric tester
TROUBLESHOOTING
No power Intermittent power
· Dead battery · Loose battery cable connection
· Disconnected battery cable · Loose charging system connection
· Fuse burned out · Loose connection or short circuit in
· Faulty ignition switch lighting system
Low power Charging system failure
· Weak battery · Loose, broken or shorted wire or connector
· Loose battery connection · Faulty regulator/rectifier
· Charging system failure · Faulty A.C. generator
· Faulty regulator/rectifier