15. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR ATV 50
When measuring current using a
tester, set it to a high range, and then
bring the range down to an
appropriate level. current flow higher
than the range selected may blow out
the fuse in the tester.
While measuring current, do not turn
the ignition switch "ON".A sudden
surge of current may blow out the
fuse in the tester.
Specified current leakage: 1 maximum
If current leakage exceeds the specified
value, a shorted circuit is likely.
Locate the short by disconnecting
connections one by one and measuring the
current.
A.C. GENERATOR INSPECTION
(MX'ER 50)
A.C. Generator Connector
Inspect with the engine installed.
Disconnect the A.C. generator connector.
Measure the resistances between the
charging coil terminals (whitegreen) and
lighting coil terminals (yellowgreen).
Resistances:
Charging coil Whitegreen 0.21.2
Lighting coil Yellow 0.31.0
green
Refer to 8-3 for A.C. generator removal.
15-7