          7. CYLINDER HEAD (2-STROKE)/
   CYLINDER/PISTON                                  VITALITY 50

 Remove the piston rings and insert each
 piston ring into the cylinder bottom.
 Use the piston head to push each piston
   ring into the cylinder.                   20mm
 Measure the piston ring end gap.
 Service Limit: Top: 0.5mm replace if over
                 2nd: 0.65mm replace if
                 over
 Oil ring: 0.9mm replace if over




 Measure the piston pin hole I.D.
 Service Limit: 13.04mm replace if over




 Measure the piston pin O.D.
 Service Limit: 12.96mm replace if below