          16. ELECTRICAL EQUIPMENT                                     VITALITY 50

 Inspect the ignition coil with an ignition
 coil tester.

    Follow the ignition coil tester manufac-
    turer`s instructions.
 1. Turn the changeover switch to 12V and
    connect the ignition coil to the tester.
 2. Turn the power switch ON and check the
    spark from the watch window.
 Good : Normal and continuous spark
 Faulty : Weak or intermittent spark

    The test is performed at both conditions
    that the ignition coil is cold and hot.



                                               Blue/Yellow
 A.C. GENERATOR
 Exciter Coil/Pulser Coil Inspection

   This test is performed with the stator
   installed in the engine.
 Remove the met-in box and center cover.
 ( 13-5)

 Disconnect the A.C. generator wire
 connector.
 Measure the pulser coil resistance between
 the blue/yellow wire and ground.
 Resistance (20):
 2-Stroke: 80160

                                                             Blue/Yellow
 Resistance (20):
 4-Stroke: 118.1118.2




                                                                     16-14