          17. INSTRUMENT/SWITCHES/LIGHTS                                      VITALITY 50

                                                            Flange
 INSTALLATION
 The installation sequence is the reverse of
 removal.
 · Align the groove on the fuel unit with
     the flange on the fuel tank.




                                                           Groove




 OIL METER (2-STROKE)
 INSPECTION
 Remove the rear body cover. ( 13-6)           Oil Meter                     B
                                                            G/R B        G
 Disconnect the oil meter wire connectors
 and remove the oil meter. Keep the oil
 meter float at the lower position.
 Measure the resistances between the wire
 terminals as and shown in the left
 figure.

      Wire Terminals            Resistance
  Green/Red(+)Black(-)              46
    Green(-)Black(+)                               Float

 Before removing the oil meter, be sure
   to drain the motor oil and do not allow
   sparks or flames near the working area.




17-3