          15. ELECTRICAL EQUIPMENT                               SUPER8 50 2T



 Performance Test
 Remove the ignition coil.




                                                   Ignition Coil
 Inspect the ignition coil with an ignition coil
 tester.

    Follow the ignition coil tester manufac-
    turer`s instructions.

 1. Turn the changeover switch to 12V and
    connect the ignition coil to the tester.
 2. Turn the power switch ON and check the
    spark from the watch window.
 Good : Normal and continuous spark
 Faulty : Weak or intermittent spark

    The test is performed at both conditions
    that the ignition coil is cold and hot.




 A.C. GENERATOR
 Exciter Coil/Pulser Coil Inspection

   This test is performed with the stator
   installed in the engine.
 Remove the met-in box. ( 12-4)
 Disconnect the A.C. generator wire
 connector.
 Measure the pulser coil resistance between
 the blue/yellow wire and ground.
 Resistance (20): 100150




15-9