20. LIGHTS/SWITCHES UXU 500
FUEL UNIT
REMOVAL
Remove the seat
Remove the fuel unit connectors.
Remove fuel unit from fuel tank.
INSPECTION
Measure the resistance between the
Yellow/White and Blue/White terminals of
the fuel unit connector.
Standard (at 20°C/68°F):
Float at full position 1100 3%
Float at empty position 100 3%
Full Empty
INSTALLATION
Fuel unit installation is in the reverse order
of removal.
Align the tab on the fuel unit with the
mark on the fuel tank.
20-9