          5. FUEL SYSTEM                                                              AGILITY 50
                                                                                Valve Seat
 INSPECTION
 Inspect the float valve and valve seat for
 damage or clogging.
 Inspect the float valve and valve seat
 contact area for stepped wear or
 contamination.
 Worn or contaminated float valve and
    valve seat must be replaced because it
    will result in float level too high due to
    incomplete airtightness.


                                                                Needle Jet Holder     Slow Jet
 ASSEMBLY
 Install the slow jet, needle jet, needle jet
 holder, main jet and pilot screw.
 Return the pilot screw to the original
    position as noted during removal.

 Standard Opening: 21/2 turns



                                                 Pilot Screw   Needle Jet               Main Jet
                                                  Float                             Float Valve
 Install the float valve, float and float pin.
 Secure the float pin with the screw.




 FLOAT LEVEL INSPECTION                            Float Pin                          Screw

 · Check the operation of the float valve
     and float before this inspection.
   · Measure the float level by placing the
     float level gauge on the float chamber
     face parallel with the main jet.
 Measure the float level.
 Float Level: 17.0mm

 This installation sequence is the reverse of
 removal.
                                                 Float Level Gauge

5-9