          11. CRANKCASE/CRANKSHAFT                                     VITALITY 50

 Remove the crankshaft from the left           Crankshaft
 crankcase.




                                          Dowel Pins
 Remove the cam chain.
 Remove the gasket and dowel pins.




                                            Gasket          Cam Chain




 Clean off all gasket material from the
 crankcase mating surfaces.
 Avoid damaging the crankcase mating
   surfaces.


                                           Axial                    Radial




11-11