          18. STARTING SYSTEM                                               GRAND DINK 250


 STARTER MOTOR CASE
 CONTINUITY CHECK
 Check to confirm that there is no continuity
 between the starter motor wire terminal and
 the motor front cover.
 Also check for the continuity between the
 wire terminal and each brush.
 Replace if necessary.



                                                  Wire Terminal

 Measure the length of the brushes.
 Service Limit: 8.5mm replace if below




 Check for continuity between the brushes. If
 there is continuity, replace with new ones.




 Check if the needle bearing in the front cover           Bushing
 turns freely and has no excessive play.
 Replace if necessary.
 Check the dust seal for wear or damage.




                                                            Dust Seal