          15. ELECTRICAL EQUIPMENT                                              ZX / SCOUT 50

                                                            Starter Relay
 STARTER RELAY INSPECTION
 Remove the battery cover.
 Disconnect the starter relay coupler and
 then remove the starter relay.




                                                Red             Yellow/Red
 Connect the starter relay green/yellow
 terminal to the 12V battery positive (+)
 terminal and the relay yellow/red terminal
 to the battery negative (-) terminal. Check
 for continuity between the starter relay red
 and red/white terminals. The relay is
 normal if there is continuity.




                                                Red/White        Green/Yellow


                                                             Bolts
 STARTER MOTOR REMOVAL
 Disconnect the starter motor cable.
 Remove the two bolts attaching the starter
 motor and remove the starter motor.

 The installation sequence is the reverse of
 removal.




                                                Starter Motor